Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Catheter Cardiovasc Interv ; 99(1): 181-192, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34402588

RESUMO

OBJECTIVES: The objective was to compare outcomes of redo-aortic valve replacement (AVR) via surgical or transcatheter approach in prior surgical AVR with large percentage of prior stentless surgical AVR. BACKGROUND: With the introduction of transcatheter aortic valve replacement (TAVR), patients with increased surgical risks now have an alternative to redo surgical AVR (SAVR), known as valve-in-valve (ViV) TAVR. Stentless prosthetic aortic valves present a more challenging implantation for ViV-TAVR given the lack of structural frame. METHODS: We performed a retrospective study of 173 subjects who have undergone SAVR (N = 100) or ViV-TAVR (N = 73) in patients with prior surgical AVR at Wake Forest Baptist Medical Center from 2009 to 2019. Our study received the proper ethical oversight. RESULTS: The average ages in redo-SAVR and ViV-TAVR groups were 58.03 ± 13.86 and 66.57 ± 13.44 years, respectively (p < 0.0001). The redo-SAVR had significantly lower STS (2.78 ± 2.09 and 4.68 ± 5.51, p < 0.01) and Euroscores (4.32 ± 2.98 and 7.51 ± 8.24, p < 0.05). The redo-SAVR group had higher percentage requiring mechanical support (8% vs. 0%, p < 0.05) and vasopressors (53% vs. 0%, p < 0.0001), longer length of stay (13.65 ± 11.23 vs. 5.68 ± 7.64 days, p < 0.0001), and inpatient mortality (16% vs. 2.78%, p < 0.005). At 30-day follow-up, redo-SAVR group had higher rates of acute kidney injury (10% vs. 0%, p < 0.01), however ViV-TAVR group had more new left bundle branch blocks (6.85% vs. 0%, p < 0.05). No significant differences regarding re-hospitalization rates, stroke, or death up to 1-year. CONCLUSION: Although the ViV-TAVR group had higher risk patients, there were significantly fewer procedural complications, shorter length of stay, and similar mortality outcomes up to 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 97(5): 905-909, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33098361

RESUMO

OBJECTIVES: This study aimed to assess the feasibility, efficacy, and safety of a novel percutaneous postprocedure closure technique for large arterial sheath removal with the use of two Perclose ProGlide (Abbott Vascular Devices, Redwood City, CA) devices. BACKGROUND: Postprocedural closing of large-bore arteriotomies using the Perclose system can be difficult given the subsequent inability of the device to capture sufficient wall tissue. METHODS: Our study was a single-center retrospective analysis of 22 consecutive patients who underwent large arteriotomy closure via the postclosure technique with a 12-16-Fr sheath. Efficacy endpoints included successful deployment of the system and hemostasis. Safety endpoints included the incidence of major or minor vascular complications as defined by the Vascular Academic Research Consortium-2 (VARC-2) definitions at 30-day follow-up. RESULTS: The postclosure technique resulted in 100% technical success rate and no postprocedural bleeding or vascular complications. CONCLUSION: Postclosure technique is a safe, highly effective, and feasible percutaneous method to achieve large-bore arteriotomy hemostasis with low rates of major bleeding or vascular complications and favorable early outcome.


Assuntos
Artéria Femoral , Dispositivos de Oclusão Vascular , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Técnicas Hemostáticas/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares
3.
J Am Heart Assoc ; 9(7): e013827, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32200711

RESUMO

Background Heart rate variability (HRV) is associated with vascular risk factors for dementia, but whether HRV is associated with specific domains of cognitive performance is unclear. Methods and Results In the Multi-Ethnic Study of Atherosclerosis (N=3018; mean age 59.3±9.2 years), we assessed the relationship of 10-second HRV to scores on tests of global cognitive performance (Cognitive Abilities Screening Instrument), processing speed (Digit Symbol Coding), and working memory (Digit Span). HRV was computed as the SD of normal-normal intervals (SDNN) and root mean square of successive differences (RMSSD) at Exam 1 (2000-2002) and Exam 5 (2010-2012). Cognitive tests were administered at Exam 5. We report regression coefficients (ß [95% CI]) representing cognitive test score change per 2-fold increase in HRV. After adjustment for age, race/ethnicity, sex, education, apolipoprotein E genotype, and cardiovascular risk factors and incident disease, higher Exam 1 (ß=0.37 [0.06, 0.67]) and Exam 5 (ß=0.31 [0.04, 0.59]) SDNN were associated with better Cognitive Abilities Screening Instrument performance. Higher Exam 1 (ß=0.80 [0.17, 1.43]) and Exam 5 (ß=0.63 [0.06, 1.20]) SDNN, and Exam 5 RMSSD (ß=0.54 [0.01, 1.08]) were associated with better Digit Symbol Coding performance. Finally, higher Exam 5 SDNN was associated with better Digit Span performance (ß=0.17 [0.01, 0.33]). Associations were attenuated after adjustment for resting heart rate. Conclusions Higher HRV is generally associated with better cognitive performance in this multi-ethnic cohort of aging adults, and further study of the relationship of autonomic function to cognition is warranted.


Assuntos
Sistema Nervoso Autônomo/fisiologia , Cognição , Frequência Cardíaca , Coração/inervação , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Envelhecimento Cognitivo , Estudos Transversais , Eletrocardiografia , Feminino , Nível de Saúde , Humanos , Masculino , Memória , Saúde Mental , Pessoa de Meia-Idade , Testes Neuropsicológicos , Prognóstico , Estudos Prospectivos , Fatores Raciais , Fatores de Tempo , Estados Unidos
4.
Eur J Gastroenterol Hepatol ; 32(3): 291-302, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32012141

RESUMO

The utility of thromboelastography/thromboelastometry currently has unvalidated clinical benefit in the assessment and reversal of coagulopathy among cirrhotic patients as compared to standard coagulation testing. A novel systematic review and meta-analysis was conducted in order to assess pooled outcome data among patients receiving thromboelastography/thromboelastometry as compared to standard coagulation testing. As compared to standard coagulation testing, there was a significant reduction in the number of patients requiring pRBC, platelet, and fresh frozen plasma transfusions among thromboelastography/thromboelastometry group with pooled OR 0.53 (95% CI 0.32-0.85; P = 0.009), 0.29 (95% CI 0.12-0.74; P = 0.009), and 0.19 (95% CI 0.12-0.31; P < 0.00001), respectively. Similarly, there was a significant reduction in number of pRBC, platelet, and fresh frozen plasma units transfused in the thromboelastography/thromboelastometry group with pooled MD -1.53 (95% CI -2.86 to -0.21; P = 0.02), -0.57 (95% CI -1.06 to -0.09; P = 0.02), and -2.71 (95% CI -4.34 to -1.07; P = 0.001), respectively. There were significantly decreased total bleeding events with pooled OR 0.54 (95% CI 0.31-0.94; P = 0.03) and amount of intraoperative bleeding during liver transplantation with pooled MD -1.46 (95% CI -2.49 to -0.44; P = 0.005) in the thromboelastography/thromboelastometry group. Overall, there was no significant difference in mortality between groups with pooled OR 0.91 (95% CI 0.63-1.30; P = 0.60). As compared to standard coagulation testing, a thromboelastography/thromboelastometry-guided approach to the assessment and reversal of cirrhotic coagulopathy improves overall number of patients exposed to blood product transfusions, quantity of transfusions, and bleeding events.


Assuntos
Transtornos da Coagulação Sanguínea , Tromboelastografia , Transtornos da Coagulação Sanguínea/diagnóstico , Transtornos da Coagulação Sanguínea/etiologia , Transtornos da Coagulação Sanguínea/terapia , Testes de Coagulação Sanguínea , Transfusão de Sangue , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico
5.
Nutr Metab Cardiovasc Dis ; 30(1): 123-131, 2020 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-31753783

RESUMO

BACKGROUND: South Asians are the second fastest growing ethnic group in the United States, and they have a high risk for cardiovascular disease (CVD). Moderate alcohol consumption has been associated with lower CVD risk in some race/ethnic groups, but the association of alcohol consumption and atherosclerosis in South Asians has not been investigated. METHODS AND RESULTS: We used data from 906 South Asian participants who participated in the Mediators of Atherosclerosis in South Asians Living in America (MASALA) cohort (2010-2012). Alcohol consumption was ascertained via questionnaire, coronary artery calcium (CAC) was measured with computed tomography, and common carotid artery intima-media thickness (cIMT) was measured using B-mode ultrasonography. We used multivariable regression models to examine cross-sectional associations of alcohol consumption with the presence and amount of CAC and cIMT. Compared with never drinkers, participants consuming 4-7 drinks/week had a 63% decreased odds of any CAC after adjusting for potential confounders and mediators. Participants consuming 4-7 drinks/week had significantly lower odds of CAC score between 1 and 300 [OR (95% CI): 0.34 (0.16-0.72)]. A similar inverse association was seen for the odds of CAC>300 [OR (95% CI): 0.28 (0.07-0.97)]. Alcohol consumption of >7 drinks/week was associated with a 0.096 mm increase in common-cIMT. CONCLUSION: There was an inverse association between the amount of alcohol intake and CAC among South Asians while a positive association was found between alcohol consumption and common-cIMT. Long-term follow-up of the MASALA cohort will examine prospective associations of alcohol intake with the progression of subclinical atherosclerosis, incident CVD events, and mortality.


Assuntos
Consumo de Bebidas Alcoólicas/efeitos adversos , Consumo de Bebidas Alcoólicas/etnologia , Asiático , Doenças das Artérias Carótidas/etnologia , Doença da Artéria Coronariana/etnologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Doenças das Artérias Carótidas/diagnóstico por imagem , Chicago/epidemiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Medição de Risco , Fatores de Risco , São Francisco/epidemiologia , Fatores de Tempo
6.
Am J Med ; 133(3): 360-369, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31494108

RESUMO

BACKGROUND: Stroke is a frequent complication of infective endocarditis, especially infection involving left-sided valves. Management of anticoagulation in left-sided infective endocarditis is controversial as it is unclear whether anticoagulation impacts stroke and bleeding risk in patients with this condition. The objective of this study was to evaluate the effect of anticoagulation on stroke occurrence and bleeding complications in patients with left-sided infective endocarditis. METHODS: Patients admitted to a tertiary academic hospital with left-sided infective endocarditis between December 2011 and April 2018 were identified. Patients were stratified based on receipt of therapeutic anticoagulation prior to admission. The primary outcome measure was the rate of radiographically confirmed stroke at 10 weeks. RESULTS: Two-hundred and fifty-eight consecutive patients with left-sided infective endocarditis were identified. Patients receiving anticoagulation (n = 50) were older (median age 63 vs 52; P = .02), were more likely to have a history of atrial fibrillation (22% vs 8.2%; P < .01), more often had prosthetic valves (38% vs 13.9%; P < .01), and had a lower incidence of mitral valve involvement (40% vs 62%; P < .01), compared with patients not receiving anticoagulation. There was no significant difference in the rate of stroke, cerebrovascular hemorrhage, or mortality at 10 weeks between the two cohorts. CONCLUSIONS: Preexisting anticoagulation did not appear to have an effect on stroke, cerebrovascular hemorrhage, or mortality in patients with left-sided infective endocarditis at 10 weeks. Continuation of anticoagulation in patients with a definitive preexisting indication should be considered in patients with left-sided infective endocarditis in the absence of other contraindications.


Assuntos
Anticoagulantes/uso terapêutico , Endocardite/complicações , Hemorragias Intracranianas/induzido quimicamente , Acidente Vascular Cerebral/prevenção & controle , Adulto , Idoso , Endocardite/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina/epidemiologia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia
7.
Catheter Cardiovasc Interv ; 93(6): 1106-1115, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30588736

RESUMO

OBJECTIVES: The objectives of this study were to compare short- and intermediate-term clinical outcomes, procedural complications, TAVR prosthesis hemodynamics, and paravalvular leak (PVL) in stentless and stented groups. BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) is an alternative to surgical redo for bioprosthetic valve failure. There have been limited data on ViV in stentless surgical valves. METHODS: We retrospectively analyzed 40 patients who underwent ViV TAVR in prior surgical bioprosthetic valves at Wake Forest Baptist Medical Center from October 2014 to September 2017. Eighty percent (32/40) ViV TAVRs were in stentless, while 20% (8/40) were in stented bioprosthetic valves. RESULTS: The primary mode of bioprosthetic valve failure for ViV implantation in the stentless group was aortic insufficiency (78%, 25/32), while in the stented group was aortic stenosis (75%, 6/8). The ViV procedure success was 96.9% (31/32) in stentless group and 100% in stented group (8/8). There were no significant differences in all-cause mortality at 30 days between stentless and stented groups (6.9%, 2/31 versus 0%, 0/8, P = 0.33) and at 1 year (0%, 0/25 versus 0%, 0/5). In the stentless group, 34.4% (11/32) required a second valve compared to the stented group of 0% (0/8). There was a significant difference in the mean aortic gradient at 30-day follow-up (12.33 ± 6.33 mmHg and 22.63 ± 8.45 mmHg in stentless and stented groups, P < 0.05) and at 6-month follow-up (9.75 ± 5.07 mmHg and 24.00 ± 11.28 mmHg, P < 0.05), respectively. CONCLUSIONS: ViV in the stentless bioprosthetic aortic valve has excellent procedural success and intermediate-term results. Our study shows promising data that may support the application of TAVR in stentless surgical aortic valve. However, further and larger studies need to further validate our single center's experience.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Stents , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...